DC/DC Converter
THL 10 Series, 10 Watt
•
•
10 Watt in 1” x 1” package
•
•
Wide 2:1 input voltage ranges
•
•
I/O isolation voltage 1500 VDC
•
•
•
Cost optimized design
Shielded metal case with isolated
baseplate
Operating temp. range –40°C to +80°C
and up to +85°C with heat-sink
Input filter meets EN 55022 class A
without external components
Industry standard pinout
3-year product warranty
UL 62368-1 IEC 62368-1
The THL 10 is a series of industrial 10 Watt DC/DC-converters packed in the
compact 1" x 1" case and is a pin to pin replacement for the popular 1" x 2"
size products. The industrial standard pinout, the wide 2:1 input voltage range
and the input filter that meets EN 55032 Class A (conducted) without external
components make these converters easy to design in and suitable for to cost
optimize many existing and new applications.
The models have short circuit and overvoltage protection and are applicable in
temperature ranges of up to +80°C or +85°C with optional mounted heat sink.
Typical applications are instrumentation, distributed power architectures in
communication and industrial electronics.
Models
Order Code
Input Voltage
Range
THL 10-1210
THL 10-1211
THL 10-1212
THL 10-1213
THL 10-1221
THL 10-1222
THL 10-1223
THL 10-2410
THL 10-2411
THL 10-2412
THL 10-2413
THL 10-2421
THL 10-2422
THL 10-2423
THL 10-4810
THL 10-4811
THL 10-4812
THL 10-4813
THL 10-4821
THL 10-4822
THL 10-4823
9 - 18 VDC
(12 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5.1 VDC
12 VDC
15 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5.1 VDC
12 VDC
15 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5.1 VDC
12 VDC
15 VDC
+5 VDC
+12 VDC
+15 VDC
2'500 mA
2'000 mA
830 mA
670 mA
1'000 mA
416 mA
333 mA
2'500 mA
2'000 mA
830 mA
670 mA
1'000 mA
416 mA
333 mA
2'500 mA
2'000 mA
830 mA
670 mA
1'000 mA
416 mA
333 mA
Vnom
Efficiency
Imax
–5 VDC
–12 VDC
–15 VDC
1'000 mA
416 mA
333 mA
–5 VDC
–12 VDC
–15 VDC
1'000 mA
416 mA
333 mA
–5 VDC
–12 VDC
–15 VDC
1'000 mA
416 mA
333 mA
typ.
82 %
85 %
87 %
88 %
84 %
87 %
87 %
83 %
85 %
88 %
89 %
85 %
88 %
89 %
83 %
85 %
89 %
89 %
86 %
87 %
88 %
Options
THL-HS1
- Optional Heat Sink: www.tracopower.com/products/thl-hs1.pdf
www.tracopower.com
March 10, 2022
Page 1 / 4
THL 10 Series, 10 Watt
Input Specifications
Input Current
- At no load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
- At full load
24 Vin models:
48 Vin models:
Surge Voltage
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Under Voltage Lockout
Recommended Input Fuse
Input Filter
15 mA typ.
12 mA typ.
10 mA typ.
800 mA typ. (3.3 Vout model)
1'000 mA typ. (5.1 Vout model)
1'000 mA typ. (12 Vout model)
1'000 mA typ. (15 Vout model)
1'000 mA typ. (5 / -5 Vout model)
1'000 mA typ. (12 / -12 Vout model)
1'000 mA typ. (15 / -15 Vout model)
400 mA typ. (3.3 Vout model)
500 mA typ. (5.1 Vout model)
500 mA typ. (12 Vout model)
500 mA typ. (15 Vout model)
500 mA typ. (5 / -5 Vout model)
500 mA typ. (12 / -12 Vout model)
500 mA typ. (15 / -15 Vout model)
200 mA typ. (3.3 Vout model)
250 mA typ. (5.1 Vout model)
250 mA typ. (12 Vout model)
250 mA typ. (15 Vout model)
250 mA typ. (5 / -5 Vout model)
250 mA typ. (12 / -12 Vout model)
250 mA typ. (15 / -15 Vout model)
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
8.5 VDC max.
17 VDC max.
34 VDC max.
(Long term operation at undervoltage will damage
the converter.)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Voltage Balance
(symmetrical load)
- Cross Regulation
(25% / 100% asym. load)
- single output
- dual output
±2% max.
1% max.
1% max.
0.5% max.
1% max. (Output 1)
1% max. (Output 2)
dual output models: 2% max.
single output models:
dual output models:
single output models:
dual output models:
dual output models: 5% max.
3.3 Vout models:
5.1 Vout models:
12 Vout models:
15 Vout models:
5 / -5 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
80 mVp-p typ.
80 mVp-p typ.
100 mVp-p typ.
100 mVp-p typ.
80 / 80 mVp-p typ.
100 / 100 mVp-p typ.
100 / 100 mVp-p typ.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
March 10, 2022
Page 2 / 4
THL 10 Series, 10 Watt
Capacitive Load
- single output
- dual output
3.3 Vout models:
5.1 Vout models:
12 Vout models:
15 Vout models:
5 / -5 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
Minimum Load
Temperature Coefficient
Short Circuit Protection
Output Current Limitation
Transient Response
- Response Deviation
- Response Time
4'700 µF max.
2'200 µF max.
330 µF max.
220 µF max.
1'000 / 1'000 µF max.
150 / 150 µF max.
100 / 100 µF max.
Not required
±0.02 %/K max.
Continuous, Automatic recovery
110% min. of Iout max.
150% typ. of Iout max.
3% typ. / 5% max. (75% to 100% Load Step)
300 µs typ. (75% to 100% Load Step)
Safety Specifications
Safety Standards
CSA-C22.2, No. 60950-1
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/thl10
PD 3
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EMS Immunity
- Electrostatic Discharge
External filter proposal:
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
EN 55032 class A (with external filter)
FCC Part 15 class A (with external filter)
EN 55032 class A (with external filter)
FCC Part 15 class A (with external filter)
www.tracopower.com/overview/thl10
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
330 µF / 80 V
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 3 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
- Operating Temperature
Power Derating
- Case Temperature
- Storage Temperature
- High Temperature
Cooling System
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
95% max. (non condensing)
–40°C to +80°C
–40°C to +85°C (with Heat Sink)
+100°C max.
–50°C to +125°C
2.5 %/K above 60°C
3.3 %/K above 70°C (with Heat Sink)
Natural convection (20 LFM)
6'000 m max.
330 kHz typ. (PWM)
Functional Insulation
1'500 VDC
1'800 VDC
1'000 MΩ min.
- Input to Output, 60 s
- Input to Output, 1 s
- Input to Output, 500 VDC
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
March 10, 2022
Page 3 / 4
THL 10 Series, 10 Watt
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
See Cleaning Guideline:
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Environmental Compliance - REACH Declaration
- RoHS Declaration
2'000 pF max.
2'596'000 h (MIL-HDBK-217F, ground benign)
Allowed (hermetical product)
www.tracopower.com/info/cleaning.pdf
Alu alloy, black anodized coating
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2 - 4 µm)
Tin (5 - 7 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
1" x 1"
Wave Soldering
260°C / 10 s max.
15 g
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).
The SCIP number is provided on request.)
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thl10
Outline Dimensions
7.62
5.08
(0.3)
(0.2)
Dual
1
+Vin (Vcc)
+Vin (Vcc)
Bottom view
2
–Vin (GND)
–Vin (GND)
3
+Vout
+Vout
4
No pin
Common
5
–Vout
–Vout
6.0
10.2
2.5
10.16
10.16
(0.24)
(0.4)
(0.1)
(0.4)
(0.4)
(0.1)
3
4
2.5
(0.8)
5
(1.0)
Single
25.4
Pin
1
2
20.32
Pinout
25.4
(1.0)
Dimensions in mm (inch)
Tolerances: ±0.5 (±0.02)
Pin pitch tolerances ±0.25 (0.01)
Pin diameter Ø 1.0 (Ø 0.04)
© Copyright 2022 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. March 10, 2022
Page 4 / 4
很抱歉,暂时无法提供与“THL 10-2411”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+243.61391
- 3+237.51825
- 5+233.87300
- 国内价格
- 1+2302.27747
- 2+2251.61866
- 4+2203.26850
- 国内价格 香港价格
- 1+298.732721+35.71366
- 10+265.7189710+31.76685
- 25+256.9512525+30.71867
- 50+250.5088750+29.94848
- 100+244.22587100+29.19734
- 250+236.16216250+28.23332
- 500+209.81003500+25.08291